Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
802.3 10Base-T Ethernet |
802.3x Flow Control and Back Pressure |
802.3u 100Base-TX and 100Base-FX Fast Ethernet |
P1/P2 | S | S | L | L | LX | LX |
Green on | Green on | Green off | Green on | Green flashing | Green on | Green flashing |
Power On | Link rate 100Mbps | Link rate 10Mbps | Link established | Data transmitted | Link established (optical port) |
Data transmitted (optical port) |
Mode | Transmission Distance | Centre Wavelength |
Cable Size | TX Power(dBm) | RX Power(dBm) | Transmission Rate |
Multi-mode | 2km | 1310nm | 62.5/125um | -20~-10dBm | < -32dBm | 100Mbps |
Single Mode | 20km | 1310nm | 9/125um | -15~-8dBm | < -32dBm | 100Mbps |
Input | Voltage | Power | Frequency |
DC | 12-36V | Max.12.5 | N/A |
AC | 10-24V | Max.12.5 | 47~63Hz |
Operation Temperature | Storage Ambient Temperature | Humidity | Model (-W) |
-10ºC~+60ºC | -40ºC~+85ºC | 5~95% | Industrial Standard Temperature Switch |
-40ºC~+85ºC | -40ºC~+85ºC | 5~95% | Industrial Wide Temperature Switch |
Standard | Test Method | Descriptions | Testing Level |
EN55024 | EN61000-4-2 |
Electrostatic Discharge Test | 6KV Contact Discharge 8KV Air Discharge |
EN55024 | EN61000-4-3 RI |
Radiated Susceptibility | 10V/m, 80MHz-1000MHz |
EN55024 | EN61000-4-4 FTB |
Electrical Fast Transient /Burst Immunity Test | Power DM:2KV CM:2KV; Signal DM:1KV CM:1KV |
EN55024 | EN61000-4-5 VS |
Surge Immunity Test | Power, Signal DM:1KV; Power, Signal CM:2KV |
EN55024 | EN61000-4-6 CI |
Conducted Susceptibility Test | 10V rms 0.15MHz to 80MHz |
EN55024 | EN61000-4-11 Voltage Dips /Interruptions |
Voltage Interruptions and Voltage Dips Emission Immunity Test | 1 Line Cycle@1005% Dip 1-5seconds@>100% Dip |
EN55022 | CISPR 22 Radiated |
Radiated Emission Test |
Class A |
EN55022 | CISPR 22 Conducted |
Conducted Emission Test |
Class A |
CFR47, P15 |
ANSI C63.4 | Radiated Emission Test |
Class A |
EGMO5A-24VDC | Din-rail Unmanaged Switches, 5 10/100BaseT(X) ports, -10ºC to 60ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
EGMO5A-24VDC-W | Din-rail Unmanaged Switches, 5 10/100BaseT(X) ports, -40ºC to 85ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
EGMO5A-2SC-24VDC | Din-rail Unmanaged Switches,3 10/100BaseT(X) ports and 2 100BaseFX ports with SC connectors, multi-mode, 2km, -10ºC to 60ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
EGMO5A-2SC-24VDC-W | Din-rail Unmanaged Switches, 3 10/100BaseT(X) ports and 2 100BaseFX ports with SC connectors, multi-mode, 2km, -40ºC to 85ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
EGMO5A-2SSC-24VDC | Din-rail Unmanaged Switches, 3 10/100BaseT(X) ports and 2 100BaseFX ports with SC connectors, single-mode, 20km, -10ºC to 60ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
EGMO5A-2SSC-24VDC-W | Din-rail Unmanaged Switches, 3 10/100BaseT(X) ports and 2 100BaseFX ports with SC connectors, single-mode, 20km, -40ºC to 85ºC operating temperature, 12-36VDC or 10-24VAC Power Input |
Note: |